Under-Mattress Sleep Sensor Accuracy

Question assessedDoes an under-mattress sleep sensor agree with polysomnography?

KnowYourPrime evidence ratingUncertainEvidence is conflicting, inconsistent, or difficult to interpret.

It finds sleep almost every time and misses most waking time, so it overstates how long you slept. In a sleep lab the Withings Sleep Analyzer overstated sleep by 48 minutes; at home the gap was smaller, and its sleep stage estimates were further off than its sleep and wake calls.

Finding KYP-ER-0008Version 1.0Reviewed Rating rule 1.6CC BY 4.0

Why this is rated Uncertain

An under-mattress sensor reads breathing and body movement through the mattress. Lying still awake looks much like sleep to it, which is why its errors run in one direction.

Two studies of the same device, one in a lab and one at home, both reach the same mixed result: strong at detecting sleep, weak at detecting wake. Neither cleanly affirms agreement with polysomnography, so the rule rates the claim Uncertain.

How the rating rule reads this evidence
  • An anchor study was assessed but its own reported finding supports this claim only weakly, so the evidence is treated as unsettled rather than affirming.
  • An anchor study was assessed but its own reported finding supports this claim only weakly, so the evidence is treated as unsettled rather than affirming.

Key results

What this finding covers

Applies to: The Withings Sleep Analyzer under-mattress sensor compared with simultaneous polysomnography, in a lab with and without sleep disorders and at home in healthy adults.

Does not cover: Other under-mattress or smart mattress products; sleep apnea detection; wrist and ring trackers, covered in a separate finding.

Limitations

Evidence base

3 studies scored · 2 anchor · 1 supporting · Evidence last evaluated Oct 17, 2026

Anchor studies

The studies the rating rests on.

  1. Evaluation of a Contactless Sleep Monitoring Device for Sleep Stage Detection at Home in a Healthy Population: Prospective Study in Free-Living Conditions.Stefanos et al., JMIR Human Factors, 2026. doi.org/10.2196/77033 [author affiliations include Withings]
  2. Performance evaluation of an under-mattress sleep sensor versus polysomnography in > 400 nights with healthy and unhealthy sleep.Manners et al., Journal of Sleep Research, 2025. doi.org/10.1111/jsr.14480 [conflict statement: two authors had a Withings-supported research grant]

Supporting studies

Studies consistent with the claim that do not carry the rating on their own.

  1. Diagnostic value of wearable and contactless technologies for detecting obstructive sleep apnea: a systematic review and meta-analysis.Hasanain et al., Sleep & Breathing, 2025. doi.org/10.1007/s11325-025-03544-4

Version history

VersionDateRatingChange
1.0October 24, 2026UncertainFirst published.

Rating history on the research desk: Uncertain (September 29, 2026).

Cite this finding

KnowYourPrime Evidence Registry, Finding KYP-ER-0008, version 1.0, reviewed 2026-10-24. https://knowyourprime.com/evidence-under-mattress-sleep-sensor-accuracy

Machine-readable: JSON · Markdown · All findings

Related

This is KnowYourPrime's own assessment of the published evidence, rated under the KnowYourPrime evidence methodology. The rating is set by a fixed rule from the roles of the studies above and moves only when the evidence or the rule changes. Every change to the rating or the text is published as a new dated version. To report an error, write to corrections@knowyourprime.com.